NDA1504 Intelligent Data Acquisition Module |
| NDA1504 Intelligent Data Acquisition Module is used to acquire the signals of the DC voltage or DC current of transmitter with high accuracy, much more functions, trouble-free operation with disturbance, operation stability. It could be operated in the projects with severe environmental conditions such as hydraulic structures, slopes, roadways, bridges, tunnels, etc. |
|
Technical Parameters
Channel:16 Accuracy:0.05%FS 1dig. Resolution:0.01%FS Measuring Time:1-4s/ch Com.: EIA-RS485 or CANbus Data Storage:8K Power Supplies:6~7VDC Power Consumption: Standby:200 A Sleep:10mA Idle:60mA Measuring: 150 mA Operating Temp.: -10~+50 (-25~+60 ,Option) Storage Temp.:-20~+70 |
 |
Model NYW-1 Wire alignment Horizontal Displacement System |
| Model NYW-1 Wire alignment Horizontal Displacement System is used to monitor the interior horizontal displacement of the embankment. It can be operated by manual and also it can operate automatically. |
|
Technical Parameters
Standard Ranges:300,500mm Accuracy: manual: 1mm~ 5mm automatic:0.75%FS Resolution: 0.05mm Long-term zero drift: <0.5%FS/yr(automatic) Temp. Coefficient: <0.05%FS/ (automatic) |
 |
Model NJG Laser Alignment System In Vacuum Pipe |
|
Model NJG Laser Alignment System In Vacuum Pipe is designed for accuracy measuring the horizontal and vertical displacement of all kinds of straight-line structure with trouble-free operation from the environment factors. It possesses several kinds of operation modes, such as period measuring, multi-point measuring and single-point measuring. The measured data can be stored in the computer directly. |
|
Technical Parameters
Alignment Distance:50~2000m Measuring Ranges: 50mm(for two directions) Measuring Ranges of CCD: 200~300 mm or more(for two directions) Accuracy:0. 5 L 10-6 Resolution: 0.01mm |
 |
Model NDA1111 Carlson Instrument Readout |
|
Model NDA1111 Carlson Instrument Readout is designed for acquiring the signals of Carlson Instruments in all kinds of weather conditions. It can store the readings and all readings can be transmitted to a host computer. |
| Technical Parameters
Standard Ranges: Z: 0. 8000~1. 2000 R: 0. 010 ~120. 000  Accuracy: Z: 0. 0002
R: 0. 02  Resolution: Z: 0. 0001 R: 0. 01  Operating Temperature: -10 ~+50  Storage Temp.: -25 ~+60  |
 |
Model NDA1411 Vibrating Wire Readout |
| Model NDA1411 Vibrating Wire Readout is designed for acquiring the signals of Vibrating Wire Instruments in all kinds of weather conditions. It can store the readings and all readings can be transmitted to a host computer. |
|
Technical Parameters
Standard Ranges: Same as the Ranges of the Transducers Timebase Accuracy: 0.01% Resolution: 0.001 s Temp. Accuracy: 0.5  Resolution:0.1 Operating Temp.: -10 ~+50  Storage Temperature: -25 ~+60  |
 |
Model 3DM-2 Displacement Readout |
| Model 3DM-2 Displacement Readout is designed for acquiring the signals of displacement transducers in all kinds of weather conditions. It can store the readings and all readings can be transmitted to a host computer. |
|
Technical Parameters
Standard Ranges: Same as the Ranges of the Transducers Accuracy:0.025% FS Resolution: 0.01% FS Operating Temperature: -10 ~+50  Storage Temperature: -25 ~+60  |
 |
Model NDA1311 Capacitance Ratio Readout |
|
Model NDA1311 Capacitance Ratio Readout is designed for acquiring the signals of capacitance transducers in all kinds of weather conditions. It can store the readings and all readings can be transmitted to a host computer. |
|
Technical Parameters
Standard Ranges: Same as the Ranges of the Transducers Accuracy:0. 1%FS+1 dig. Resolution: 0.01%FS Operating Temperature: -10 ~+50  (Storage Temp.): -25 ~+60  |