Model SRF Capacitance Three Dimensions Jointmeter |
|
Model SRF Capacitance Three Dimensions Jointmeter is used to automatically measure the opening, the difference settlement and the difference movement in flowing direction between the blocks in structures, such as dams, ship locks and plants etc. |
|
Technical Parameters
Standard Ranges: 10,20,40 mm(for X,Y direction), 10,10,20 mm(for Z direction) Resolution: 0.01 mm Accuracy: 0.1~ 0.3 mm Long-term zero drift:<0.5%FS/yr Temp. Coefficient:<0.05%FS/ Operating Temp.:-30 ~+60 |
 |
Model 3DM Three Dimensions Displacement Transducer |
| Model 3DM Three Dimensions Displacement Transducer is used to automatically measure the opening and the deformation of the structures, such as the periphery crack of the concrete face rock-fill dams,the slopes and the fault of basements etc. This kind of transducer could be operated in the water for long time. |
|
Technical Parameters
Standard Ranges:0 to 250 mm Resolution:0.05 mm Accuracy:0.25% FS Water Pressure:2 MPa Operating Temp.:-30 ~+60  |
 |
Model GYY Inductance Pressure Transducer |
| Model GYY Inductance Pressure Transducer is used to automatically measure the uplift pressure of the concrete dam, by-pass leakage through two banks, the leakage of embankment etc. It could be also used in monitoring the water level or the other fluid level. |
|
Technical Parameters
Standard Ranges:10,25,50m Resolution:(0.05~0.1)%FS Accuracy:(0.25~0.5)%FS Long-term zero drift): <(0.25~0.5)%FS /yr Temp. Coefficient: <(0.025~0.04) %FS/ |
 |
Model NYZ Silicon Pressure Transducer |
|
Model NYZ Silicon Pressure Transducer is used to automatically measure the uplift pressure of the concrete dam, by-pass leakage through two banks, the leakage of embankment etc. It could be also used in measuring the water level or the other fluid level. |
|
Technical Parameters
Standard Ranges:10,25,50m Resolution:(0.05~0.1) %FS Accuracy:(0.25~0.5) %FS Long-term zero drift: <(0.25~0.5) %FS /yr Temp. Coefficient: <(0.025~0.04) %FS/ |
 |
NDA1104 Intelligent Data Acquisition Module |
|
NDA1104 Intelligent Data Acquisition Module is used to acquire the signals of Carlson Transducers with high accuracy, much more functions, trouble-free operation with disturbance, operation stability. It could be operated in the projects with severe environmental conditions such as hydraulic structures, slopes, roadways, bridges, tunnels etc. |
|
Technical Parameters
Channel:16 Accuracy:| RT| 0.02 ,| Z| 0.0002 Resolution:RT:0.01 , Z:0.0001 Measuring Time:2-5s/point Com.: EIA-RS485 or CANbus Data Storage:8K Power Supplies: 6~7VDC Power Consumption): Standby:200 A Sleep:10mA Idle:60mA Measuring: 150 mA Operating Temp.:-10 ~+50 (-25~+60 ,Option) Storage Temp.:-20 ~+70 |
 |
NDA1203 Intelligent Data Acquisition Module |
| NDA1203 Intelligent Data Acquisition Module is used to acquire the signals of differential inductance transducers with high accuracy, much more functions, trouble-free operation with disturbance, operation stability. It could be operated in the projects with severe environmental conditions such as hydraulic structures, slopes, roadways, bridges, tunnels, etc. |
|
Technical Parameters
Channel:8 Accuracy:0.05% FS Resolution:0.01%FS Measuring Time:2-5s/point Com.: EIA-RS485 or CANbus Data Storage:8K Power Supplies:6~7VDC Power Consumption: Standby:200 A Sleep:10mA Idle:60mA Measuring: 500 mA Operating Temp.:-10 ~+50 (-25 ~+60 ,Option) Storage Temp.:-20 ~+70 |
 |
NDA1303 Intelligent Data Acquisition Module |
|
NDA1303 Intelligent Data Acquisition Module is used to acquire the signals of capacitance transducers with high accuracy, much more functions, trouble-free operation with disturbance, operation stability. It could be operated in the projects with severe environmental conditions such as hydraulic structures, slopes, roadways, bridges, tunnels etc. |
|
Technical Parameters
Channel:8 Accuracy:0.1%FS 1 dig. Resolution:0.01%FS Measuring Time:2-5s/point Com.: EIA-RS485 or CANbus Data Storage:8K Power Supplies:6~7VDC Power Consumption: Standby:200 A Sleep:10mA Idle:60mA Measuring: 300 mA Operating Temp.:-10~+50 (-25~+60 ,Option) Storage Temp.:-20~+70 |
 |
NDA1403 Intelligent Data Acquisition Module |
| NDA1403 Intelligent Data Acquisition Module is used to acquire the signals of various kinds of vibrating wire transducers with high accuracy, much more functions, trouble-free operation with disturbance, operation stability. It could be operated in the projects with severe environmental conditions such as hydraulic structures, slopes, roadways, bridges, tunnels etc. |
|
Technical Parameters
Channel:8 or 16 Timebase Accuracy: 0.01% Resolution: 0.001 s Temp. Accuracy: 0.5  Resolution:0.1 Measuring Time:2-5s/point Com.: EIA-485 or CANbus Data Storage:8K Power Supplies:6~7VDC Power Consumption: Standby:200 A Sleep:10mA Idle):60mA Measuring: 500 mA Operating Temp.:-10~+50 (-25~+60 , Option) Storage Temp.:-20~+70 |