Model RZ Capacitance Two Dimensions Coordinometer |
| Model RZ Capacitance Two Dimensions Coordinometer is used with the normal pendulum(or reverse pendulum) together to automatically measure the deflection and the displacement of structures, such as dams , ship locks, slopes, high buildings, nuclear power plants, tunnels and bridges etc. |
Technical Parameters Standard Ranges:25,50 mm Resolution:0.01 mm Accuracy: 0. 1~ 0.2 mm Long-term zero drift:<0.5%FS/yr Temp. Coefficient:<0.05% FS/ Operating temperature:-30 ~+60 |
 |
Model SRZ Capacitance Three Dimensions Coordinometer |
| Model SRZ Capacitance Three Dimensions Coordinometer is used with the normal pendulum(or reverse pendulum) together to automatically measure the horizontal and vertical displacement of structures, such as dams, ship locks, slopes, high buildings, nuclear power plants, tunnels, bridges etc. |
|
Technical Parameters
Standard Ranges:25,50 mm(for X,Y direction), 10,25 mm(for Z direction) Resolution:0.01 mm Accuracy: 0. 1~ 0.2 mm Long-term zero drift:<0.5%FS/yr Temp. Coefficient.:<0.05% FS/ Operating Temp.:-30 ~+60  |
 |
Model RY Capacitance Wire Alignment Transducer |
|
Model RY Capacitance Wire Alignment Transducer is used with the wire alignment together to automatically measure the horizontal displacement of structures, such as dams, ship locks, tunnels etc. |
| Technical Parameters
Standard Ranges:20 , 40 mm Resolution:0.01 mm (Accuracy: 0. 1~ 0.2 mm Long-term zero drift:<0.5%FS/yr Temp. Coefficient:<0.05%FS/  Operating Temp.:-30 ~+60  |
 |
Model SRY Capacitance Two Dimensions Wire Alignment Transducer |
|
Model SRY Capacitance Two Dimensions Wire Alignment Transducer is used with the wire alignment (with no floats) together to automatically measure the horizontal and vertical displacement of structures, such as dams, ship locks, tunnels etc. |
|
Technical Parameters
Standard Ranges:20, 40 mm (for Y direction); 10,20 mm (for Z direction) Resolution:0.01 mm Accuracy: 0. 1~ 0.2 mm Long-term zero drift:<0.5%FS/yr Temp. Coefficient:<0.05%FS/  Operating Temp.:-30 ~+60  |
 |
Model RJ Capacitance Multipoint Leveling Transducer |
| Model RJ Capacitance Multipoint Leveling Transducer is used to automatically measure the vertical displacement of structures, such as dams, ship locks, tunnels, mines, slopes, bridges, high buildings, basements and nuclear power plants etc. |
|
Technical Parameters
Standard Ranges:20,40,50,100mm Resolution: 0.01mm Accuracy: 0. 1~ 0.3mm (Long-term zero drift):<0.5%FS/yr Temp. Coefficient:<0.05%FS/ Operating Temp.:-30 ~+60 |
 |
Model YL Capacitance Weir Gauge |
| Model YL Capacitance Weir Gauge is used to automatically measure the leakage in the drainage ditch, and to offer the leakage data for dam safety monitoring. |
|
Technical Parameters
Standard Ranges:80,100mm Accuracy: 0. 1~ 0.3mm Long-term zero drift:<0.5%FS/yr Temp. Coefficient:<0.05%FS/ |
 |
Model RW Capacitance Displacement Transducer |
| Model RW Capacitance Displacement Transducer is used to automatically measure the relative displacement of two points on structures, the deformation of the basement rocks, stability of the slopes and the opening of the cracks. |
|
Technical Parameters
Standard Ranges:10,20,40,50,100,200mm Resolution: 0.01mm Accuracy: 0. 1~ 0.3mm Long-term zero drift:<0.5%FS/yr Temp. Coefficient:<0.05%FS/ Operating Temperature:-30 ~+60 |
 |
Model DRW Capacitance Multiple Point Rod Extensometer |
| Model DRW Capacitance Multiple Point Rod Extensometer is used to automatically measure the deformation of the engineering, such as the structure basements, rocks, undergrounds, tunnels and the slopes etc. |
|
Technical Parameters
Standard Ranges:10, 20, 40, 50, 100 mm Resolution: 0.01mm Accuracy: 0. 1~ 0.3mm Long-term zero drift:<0.5%FS/yr Temp. Coefficient:<0.05%FS/ Operating Temp.:-30 ~+60 |
 |
Model RF Capacitance Two Dimensions Jointmeter |
| Model RF Capacitance Two Dimensions Jointmeter is used to automatically measure the opening and difference settlement between the blocks in structures, such as dams, ship locks and plants, etc |
|
Technical Parameters
Standard Ranges:10,20,40mm Resolution:0.01mm Accuracy: 0. 1~ 0.2mm Long-term zero drift:<0.5%FS/yr Temp. Coefficient:<0.05%FS/ Operating Temperature:-30 ~+60 |