Instruments & System for Safety Monitoring (I)

Model RZ Capacitance Two Dimensions Coordinometer
Model RZ Capacitance Two Dimensions Coordinometer is used with the normal pendulum(or reverse pendulum) together to automatically measure the deflection and the displacement of structures, such as dams , ship locks, slopes, high buildings, nuclear power plants, tunnels and bridges etc.
 Technical Parameters
Standard Ranges:25,50 mm
Resolution:0.01 mm
Accuracy:0. 1~0.2 mm
Long-term zero drift:<0.5%FS/yr
Temp. Coefficient:<0.05% FS/
Operating temperature:-30 ~+60
   Model SRZ Capacitance Three Dimensions Coordinometer
 Model SRZ Capacitance Three Dimensions Coordinometer is used with the normal pendulum(or reverse pendulum) together to automatically measure the horizontal and vertical displacement of structures, such as dams, ship locks, slopes, high buildings, nuclear power plants, tunnels, bridges etc.

Technical Parameters

Standard Ranges:25,50 mm(for X,Y direction),
10,25 mm(for Z direction)
Resolution:0.01 mm
Accuracy:0. 1~0.2 mm
Long-term zero drift:<0.5%FS/yr
Temp. Coefficient.:<0.05% FS/
Operating Temp.:-30~+60

   Model RY Capacitance Wire Alignment Transducer

Model RY Capacitance Wire Alignment Transducer is used with the wire alignment together to automatically measure the horizontal displacement of structures, such as dams, ship locks, tunnels etc.

 Technical Parameters

Standard Ranges:20 , 40 mm
Resolution:0.01 mm
(Accuracy:0. 1~0.2 mm
Long-term zero drift:<0.5%FS/yr
Temp. Coefficient:<0.05%FS/
Operating Temp.:-30 ~+60

   Model SRY Capacitance Two Dimensions Wire Alignment Transducer

Model SRY Capacitance Two Dimensions Wire Alignment Transducer is used with the wire alignment (with no floats) together to automatically measure the horizontal and vertical displacement of structures, such as dams, ship locks, tunnels etc.

Technical Parameters

Standard Ranges:20, 40 mm (for Y direction);
10,20 mm (for Z direction)
Resolution:0.01 mm
Accuracy:0. 1~0.2 mm
Long-term zero drift:<0.5%FS/yr
Temp. Coefficient:<0.05%FS/
Operating Temp.:-30 ~+60

  Model RJ Capacitance Multipoint Leveling Transducer
Model RJ Capacitance Multipoint Leveling Transducer is used to automatically measure the vertical displacement of structures, such as dams, ship locks, tunnels, mines, slopes, bridges, high buildings, basements and nuclear power plants etc.

Technical Parameters

Standard Ranges:20,40,50,100mm
Resolution: 0.01mm
Accuracy:0. 1~0.3mm
(Long-term zero drift):<0.5%FS/yr
Temp. Coefficient:<0.05%FS/
Operating Temp.:-30~+60

  Model YL Capacitance Weir Gauge
Model YL Capacitance Weir Gauge is used to automatically measure the leakage in the drainage ditch, and to offer the leakage data for dam safety monitoring.

Technical Parameters

Standard Ranges:80,100mm
Accuracy:0. 1~0.3mm
Long-term zero drift:<0.5%FS/yr
Temp. Coefficient:<0.05%FS/

  Model RW Capacitance Displacement Transducer
Model RW Capacitance Displacement Transducer is used to automatically measure the relative displacement of two points on structures, the deformation of the basement rocks, stability of the slopes and the opening of the cracks.

Technical Parameters

Standard Ranges:10,20,40,50,100,200mm
Resolution: 0.01mm
Accuracy:0. 1~0.3mm
Long-term zero drift:<0.5%FS/yr
Temp. Coefficient:<0.05%FS/
Operating Temperature:-30~+60

  Model DRW Capacitance Multiple Point Rod Extensometer
Model DRW Capacitance Multiple Point Rod Extensometer is used to automatically measure the deformation of the engineering, such as the structure basements, rocks, undergrounds, tunnels and the slopes etc.

Technical Parameters

Standard Ranges:10, 20, 40, 50, 100 mm
Resolution: 0.01mm
Accuracy:0. 1~0.3mm
Long-term zero drift:<0.5%FS/yr
Temp. Coefficient:<0.05%FS/
Operating Temp.:-30~+60

  Model RF Capacitance Two Dimensions Jointmeter
Model RF Capacitance Two Dimensions Jointmeter is used to automatically measure the opening and difference settlement between the blocks in structures, such as dams, ship locks and plants, etc

Technical Parameters

Standard Ranges:10,20,40mm
Resolution:0.01mm
Accuracy:0. 1~0.2mm
Long-term zero drift:<0.5%FS/yr
Temp. Coefficient:<0.05%FS/
Operating Temperature:-30~+60